Skip to content

Fibre Splicing, Termination & OTDR Testing in Oman

Novatelia splices, terminates and tests fibre optic links in-house, using its own COMWAY fusion splicers and a Fluke DSX-8000 Versiv 2 tester with an OTDR Quad module. Novatelia is based in Muscat; send the route, fibre count and test requirement for a quotation.

IN-HOUSE

What we do in-house

Fusion splicing, termination and OTDR testing are carried out by Novatelia with its own equipment: COMWAY fusion splicers and a Fluke DSX-8000 Versiv 2 with an OTDR Quad module.

  • Fusion splicing of single-mode and multimode fibre.
  • Pigtail splicing into optical distribution frames, cassettes and closures.
  • Termination with LC, SC or MPO connectors.
  • OTDR testing, with a test record for each fibre tested.

Fusion splicing and termination

Fibres are fusion spliced into splice trays, optical distribution frames or closures, protected with heat-shrink splice protectors and labelled. The splice loss is recorded in the project test record.

OTDR testing

An OTDR trace shows each event along a fibre: the fibre length, the loss and reflectance of splices and connectors, and the location of a fault or break. Single-mode fibre is commonly tested at 1310 nm and 1550 nm. The pass/fail limits are the ones set in the project or consultant specification.

What you receive at handover

The test results exported from the tester, with the OTDR trace and result for each fibre tested, together with the fibre and port schedule and the labels. The report format is confirmed in the quotation.

When to ask for splicing and testing

  • New backbone or inter-building fibre links.
  • Extensions to an optical distribution frame.
  • Locating and repairing a fibre fault.
  • Acceptance testing of a link installed by another contractor.
  • Before moving a link to higher-speed optics; see compatible SFP transceivers and fibre distance planning.

Supply plus service in one quotation

Fibre optic cable, ODFs and patch cords, together with pigtails and closures, can be quoted with the splicing and testing in one quotation. For design and installation see fiber optic and structured cabling, for other acceptance tests see testing, validation and handover, and for transport networks see fibre transport and FTTH backbones. Choosing the fibre type is covered in single-mode vs multimode fiber.

MUHAMMED JAN MAJEEDI TRADING SPC

South Al Udhaybah, Bousher, P.O. Box 58, PC 111, Muscat, Sultanate of Oman

+968 7808 2410 · [email protected]

See our Muscat office.

How to request a quote

Include these details in the request:

  • Site and route.
  • Fibre type and fibre count.
  • Number of splices and terminations.
  • Connector type.
  • Test requirement and wavelengths.
  • Report format.
  • Access or permit constraints.

Fibre splicing and OTDR testing — questions and answers

01

Do you do fibre splicing and OTDR testing in-house?

Yes. Novatelia uses its own COMWAY fusion splicers and a Fluke DSX-8000 Versiv 2 tester with an OTDR Quad module for splicing, termination and OTDR testing.

02

Are you an authorized Fluke Networks partner?

No Fluke Networks partner title is claimed. Novatelia owns and uses the tester; it is not a Fluke Networks distributor or service centre.

03

What does an OTDR report show?

The trace of each fibre: its length, splice and connector events with their loss and reflectance, and the end of the fibre. It also locates faults. Pass/fail limits come from the project specification.

04

Can you test a link installed by another contractor?

Testing of existing links can be quoted. Scope, access and acceptance limits are agreed in writing first.

05

Do you publish prices for splicing or testing?

No. Each job is quoted from the route, fibre count, number of splices and test requirement.

Related fibre pages

  • Fiber leads dressed into an optical patch field

    Fibre Optic Cable, Panels & Testers

    Fibre cable, ODFs, pigtails, patch cords and closures for the same project.

    Open solution
  • Enterprise switch with blue patch leads seated in the ports

    Testing, Validation & Handover

    The optical tests and handover records named for the project.

    Open solution

Send the route, fibre count and test requirement

The RFQ page keeps a browser draft. It does not submit a quotation or issue a reference.