Skip to content

Overview

Key features The Fluke 975 offers an unparalleled featureset for HVAC and facilities technicians, helping them work more quickly and accurately, with the ease of use and durability customers expect from a Fluke meter. Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display One-touch air flow and velocity with available probe* Wet bulb and dew point temperature % of outside air calculation CO2 and CO field calibration feature Self-test function at startup Auto-backlight Automatically compensates for barometric pressure changes Min/Max/Average on all measured and calculated readings Multi-language user interface Metric or standard units Audible and visual threshold alarms Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface Keypad lock for security Included FlukeView Forms® software *Included with Fluke 975V, optional with Fluke 975 Product overview: One Tool. Get More Done. The Fluke 975 AirMeter test tool raises indoor air monitoring to the next level by combining five powerful tools in one, rugged and easy-to-use handheld device. Use the Fluke 975 to optimize HVAC ventilation settings for ASHRAE 62 recommendations, actively monitor conditions that promote a productive environment, and quickly and accurately address occupant comfort complaints the first time. The Fluke 975 measures: Temperature Velocity Humidity CO2 CO Use the Fluke 975 AirMeter test tool to: Respond to comfort-related calls from occupants. Verify the operation of building HVAC control systems. Determine whether adequate ventilation exists. Monitor air flow and velocity. Test for dangerous carbon monoxide leaks. Perform duct traversals. Optimize HVAC systems to manage energy costs Specifications: Measured Specifications Temperature Range -20°C to 50°C (-5°F to 122°F) Display resolution 0.1°C (0.1°F) Accuracy ±0.9°C \/ ±1.62°F from 40°C to 60°C ±0.5°C \/ ±1.00°F from 5°C to 40°C ±1.1°C \/ ±1.98°F from -20°C to 5°C Relative humidity Range 10% to 90% RH, non-condensing Display resolution 1% Accuracy ±2% RH (10% RH to 90% RH) Air velocity Range 50.0 fpm to 3000 fpm 0.25 m\/sec to 15 m\/sec Display resolution 1 fpm (0.005 m\/sec) Accuracy ±4% or 4 fpm1 ±4% or 0.02 m\/sec1 whichever is greater 1. Accuracy specification only valid for velocity readings above 50 fpm. C0 Range 0 to 500 ppm Display resolution 1 ppm Accuracy ±5% or ±3 ppm, whichever is greater, @ 20°C and 50% RH C02 Range 0 to 5000 ppm Display resolution 1 ppm Accuracy Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm Calculated Specifications Dew point temperature Range -44°C to 50°C, (-47°F to 122°F) Display resolution 0.1°C (0.1°F) Accuracy ±1°C when temp: -20°C to 50°C RH: 40% to 90% ±2°C when temp: -20°C to 50°C RH: 20% to 40% ±4°C when RH: 10% to 20% Wet bulb temperature Range -16°C to 50°C, (3°F t Data sheet: 975 Data Sheet - English Manuals: 975

Part number
59-07-0975
Brand
Fluke
Category
Tools & Equipment
Product type
Test Equipment

Related products